Minimum Film-Forming Temperature Tester

BGD 452 Minimum Film-Forming Temperature(MFFT)Tester

Base price
MFFT 2
MFFT Spec
Description

As the most important component--emulsions for coatings and polymer dispersions

for coatings and plastics polymer, its film-forming property has important influence on

final products drying property. Thus, knowing its MFFT is very necessary.

In a certain temperature, emulsions or polymer dispersions, if the temperature is not high enough, then can’t let the polymer particles polymerize. Now, all polymer particles can’t get

together any more and then form incontinuous and non-transparent white mass; If the

temperature is high enough and let the particles get together, then can form continuous and

transparent film.

White Point TemperatureThe dividing temperature when non-transparent film change to transparent film.

Minimum Film-forming TemperatureThe lowest temperature when forming

continuous, uniform and no-crack filmGenerally speaking, White Point Temperature has

serval degrees lower than MFFT

BGD 452 Minimum Film-Forming TemperatureMFFTTester is the newest

instruments which is developed by Biuged lately, Its main structure is a metalcopper

platen with an electronically imposed temperature gradient. Built in temperature sensors

monitor the temperature across the platen, a graph of the gradient is displayed on the

touch screen. A cooling source and a heating source are located separately on the two

ends of platen to produce different temperature gradient through metal heat conduction

theory.

Applicate a continuous and uniform thickness wet film of emulsion or dispersions on the

temperature gradient platen, then dry it by dry air, with temperature of platen influence, the water of sample would evaporate and form film. Due to different temperature on the platen, the film-forming position is also different. Find the dividing point between continuous

transparent film with white non-transparent film, thus this point which also can be read from touch screen of tester is MFFT.

It is accordance with ISO 2115, ASTM D 2354 standard, and can test minimum film

temperature of emulsion polymer easily and accurately. 

Features

 Initiated in China, High-tech product, combine a lot of patents with independent

intellectual property rights.

 Small size, high precision, intelligent operation, easy to use and maintenance.

 Color touch screen+ menu operation system, all parameters can be shown in real time

 High precision digital temperature sensor, ensure the temperature error is less than

0.1

 Come with chiller

 Optional Dry Air Generator which can produce dry dew point air ,and can ensure

<span style="font-size: 11.0pt; font-family: 'Arial','sans-serif'; color: blac