Kinetic Energy Tester Sensor Distance Select 100-500mm

KE Tester is a equipment to check the speed of a object (DUT) which pass though the test tunnel .According to the result read out and mass value of DUT, we could calculate the kinetics energy value and know how danger of DUT it is.

Base price
Description

Product Introduction

KE Tester is a equipment to check the speed of a object (DUT) which pass though the test tunnel .According to the result read out and mass value of DUT, we could calculate the kinetics energy value and know how danger of DUT it is .

Inside the test tunnel of this KE tester, there have three sets of Infra-Red sensor group. One set for start the timer and other two for stop the timer.

Each group include 30 pairs Infra-Red Sensor. They are located in opposite plate and the Infra-Red light are transmitter and receiver are fix in a opposite and signal will transmit and receive though a 1mm narrow gap.

The first group sensor is calls “Start-Sensor”. The second group is call “10cmStopSensor” and the third group is call “30cmStopSensor”.

Distance between “StartSensor” and “10cmStopSensor” is 10cm. It is always use for detect low speed or high air friction object.

Distance between “StartSensor” and “30cmStopSensor” is 30cm. It is always use for detect high speed or low air friction object.

1/10000s timer will start at “Start-Sensor” detected DUT, timer will stop until “10cmStopSensor” or “30cmStopSensor” detected DUT. (According to the test range select by user).

 

Test Standards

EN71, ASTM F963, Hasbro

 

Basic requirements

  1. 220V AC Input
  2. Turn-On the tester and let it warm up for 5min.
  3. DUT need to go through the tunnel in horizontally.
  4. Diameter of DUT need to greater than 5mm
  5. Speed of DUT must lower than 140m/s
  6. Test Time(DUT go through time must less than 2.6S

Advantage

1) 1/10000Sec Time Interval
2) Data Save and Average
3) 10-50cm Test Range Selectable
4) PC Data Out Interface
5) Termo Printer
6) Accuracy Calibrator

 

Basic Function /Specification

 Time counter interval  1/10000s
 Timer Error  <0.1ms
 Sensor distance select  10-50cm
 Sensor distance error  <0.5mm

 

Technical parameters

 Number of samples  1/time
 Maximum timing  15.000000S
 Timing range  0.000001--15.000000S
 Speed display range  0.007M/S—100M/S
 Induction spacing  100mm-500mm, error 0.1mm
 Minimum diameter of sample  5mm
 Volume(WxDxH)  47x87x72cm
 Weight (approx.)  ≈20kg
 Power supply  1∮ AC 220V 3A

 

Assist Part

  1. Bullet Simulator.
  2. 40cm wide test tunnel
  3. Keyboard
  4. PC Interface Cable
  5. 2” thermal printer
  6. Drawer
  7. //